Connecting the Battery Communication System within the Battery Cabinet
Qualified person
- Plug the 6-pole connector of the communication cable from the supplied APU connector set into the BAT COM socket on the battery management system.
- Plug the 8-pole connector of this communication cable into the COMM IN socket on the uppermost battery module. Lay the communication cable over the DC cable.
- Plug the 6-pole connector of a communication cable from the supplied module connector set into the COMM OUT socket on the uppermost battery module.
- Plug the 8-pole connector of this communication cable into the COMM IN socket on the next battery module. Lay the communication cable over the DC cable.
- Incorporate the rest of the battery modules into the communication cabling within the battery cabinet, working from top to bottom.