Integration of heat pump into the energy management
Via the SG Ready interface, it is possible to give the heat pump a switch-on recommendation when sufficient PV energy is available to raise the temperature in the buffer tank.
Switching of heat pump via compatible radio-controlled socket and separate relay
Requirements:
The radio-controlled socket must be in operation.
The separate relay must accept a 230 VAC input signal.
The heat pump must have been installed in the system and commissioned in accordance with the manufacturer specifications.
For the Sunny Home Manager this must be set: Data request interval Automatic ( > Setting the Data Request Interval).
General procedure:
- Include radio-controlled socket in the system Adding a Radio-Controlled Socket.
- Connect the heat pump to the radio-controlled socket and define basic load characteristics ( > Configuring Load Characteristics), including, for example, the correct power consumption ( > Entering the Power Consumption), the minimum running time ( > Entering the Minimum Switch-On and Switch-Off Time) and that the heat pump should only be switched ( > Setting Measuring and Switching of the Assigned Device).
- Configure the time period ( > Configuring the Time Period).
Switching the heat pump directly via compatible relay
Requirements:
The compatible relay must have been installed in the system and commissioned in accordance with the manufacturer specifications.
The heat pump must have been installed in the system and commissioned in accordance with the manufacturer specifications.
For the Sunny Home Manager this must be set: Data request interval Automatic ( > Setting the Data Request Interval).
General procedure:
- Including the compatible relay into the system
e.g. for a Modbus device: Set up Modbus connection ( > Configuring Modbus Interfaces) and include Modbus device in the system Adding Modbus Device. - Connect the heat pump to the compatible relay and define basic load characteristics ( > Configuring Load Characteristics), including, for example, the correct power consumption ( > Entering the Power Consumption), the minimum running time ( > Entering the Minimum Switch-On and Switch-Off Time) and that the heat pump should only be switched ( > Setting Measuring and Switching of the Assigned Device).
- Configure the time period ( > Configuring the Time Period).