Configuring Reports
Requirement:
You must have the user role Installer or PV System Administrator ( > User Groups and User Rights).
You can configure different types of event reports, each with different content:
Report, type | Possible content |
---|---|
3 x daily info report 3 x monthly info report |
|
3x event report |
|
1x event report for standard | Message regarding grounding errors, residual current and the grid disconnecting device
|
In addition, you can create a report for a specific date in the past.
Configuring Info Reports
Sunny Portal sends you the Daily info reports when it has processed all the data from the previous day, and the Monthly info report at the end of the month.
Requirement:
You must have entered the CO2 avoided factor ( > Entering the Amount of CO2 Avoided).
Procedure:
- In the drop-down list Report Configuration, select a Daily info report or a Monthly info report.
- Select [Edit].
- In the field Activate report, activate the checkbox Active.
- Under Recipient, enter the e-mail address(es) of the recipient(s) in the text field E-mail address(es). If you enter several e-mail addresses, separate these by commas.
- In the Contents area
at Select channel(s), activate the contents that is to be displayed in the e-mail. - At Send report as select the format in which Sunny Portal is to send the report: text, HTML format or PDF.
- At Portal page to be sent, in the drop-down list
either select the page that the Sunny Portal is to sent along with the report or select Send no page. - To send a test report to the stated e-mail address, select [Send test report].
- Click on [Save].
Configuring Event Reports
Sunny Portal sends you the event reports at the times set.
Procedure:
- In the drop-down list Report configuration, select an Event report.
- Select [Edit].
- In the field Activate report, activate the checkbox Active.
- Under Recipient, enter the e-mail address(es) of the recipient(s) in the text field E-mail address(es). If you enter several e-mail addresses, separate these by commas.
- In the Interval area, first specify how often you wish to receive an event report by e-mail by either activating the option Hourly or Daily, and then select from the drop-down list the Time you would like to receive the e-mail.
- In the Contents area activate the event types whose contents are to be displayed in the e-mail.
The Sunny Portal and the Sunny Home Manager system each offer 4 event types: information, warnings, failures and errors. - At Send report as select the format in which Sunny Portal is to send the report: text, HTML format or PDF.
- At Limit messages in one report, use the drop-down list to select the maximum number of messages to be displayed in the e-mail.
- If applicable, activate Send empty reports if no new events are available if you wish to have sent reports even it there are no new events available.
- To send a test report to the stated e-mail address, select [Send test report].
- Click on [Save].
Manually Regenerating Reports
You can create a report for a specific date in the past.
Procedure:
- Select the desired report in the drop-down list Report configuration.
- In the field Report date in the area Regenerate report manually, enter the date for which you wish to create a report, either manually or using the calendar.
- Select [Generate].
- A message that the report has been successfully sent is displayed.