Configuring Modbus Interfaces
With Sunny Home Manager, this setting is only possible under Complex configuration.
Each device that is to communicate with the Sunny Home Manager via a Modbus communication protocol must be uniquely addressed.
On the tab Modbus configuration, you can store up to 4 different Modbus configurations with which the Sunny Home Manager searches for connected devices. After a successful search, the detected devices appear on the tab Overview new devices and can be added there.
Procedure:
- Select Configuration > Device overview in the page and menu selection.
- Select the device properties of the Sunny Home Manager.
- After selecting the Extended configuration view, open the tab Modbus Configuration.
- In the Modbus Profile column, select the required predefined Modbus device from the drop-down menu.
If a Moxa device is used with an SG-ready device, for example, set up a Modbus configuration with profile MOXA1214.
If a ripple control receiver is connected to the Moxa device for external limitation of the active power feed-in, use the profile MOXA1214_PLimit. - Enter the data of the selected device in the fields IP address, Port and Unit ID.
If the Modbus device is a Moxa device, it is recommended to set the Moxa device in the router with an IP address/MAC address binding or to subsequently set to a fixed IP address from the free range of the router not used for DHCP. Port (default 502) and Unit ID (default 1 or 2) do not need to be changed.
Existing entries can be changed by overwriting.
To delete a configuration, click on the recycle bin symbol in the corresponding line. - Click on [Save].