Enabling peak shaving with increased self-consumption with single-phase battery storage systems
Prerequisites:
For projects with self-consumption:
You have opened a project and planned it up to the project page System (quick planning) or Determine self-consumption (detailed planning).
For energy system projects:
You have opened a project and planned it up to the project page Energy system.
Procedure:
- For energy systems, on the Energy system page, click the button [Battery System] in the central workspace and enable the option Take battery-storage systems into account.
- For PV systems with self-consumption, on the page System (quick planning), enable the option Take battery-storage systems into account, or on the page Determine self-consumption (detailed planning), enable the option Intermediate storage of excess PV energy.
- Select the single-phase option button.
- In the Application drop-down list, select the option Peak load shaving and increased self-consumption (multiuse).
- In the Device drop-down list, select the desired device.
- To have a suggestion for the peak load shaving limit calculated, select [Determine consumption limit]. It only makes sense to configure the following settings with a grid-supply limit that is suitable for the system.
- Select [Apply proposal].
- To define the "multiuse" function, select [Settings]. The suggestion for the grid-supply limit has been applied in the dialog box.
- In the field SOC limiting value, enter the desired value.
- If necessary, click the Adaptive increase of the grid-supply limit options.
- If the Adaptive increase of the grid-supply limit was clicked, if necessary click the Automatic reset at the end of the accounting period option button and select the duration of the accounting period.
- Click on [OK] to save the settings.