Connecting RS485
Qualified person
Additional required material (not included in the scope of delivery):
One communication cable for RS485 communication
Requirements:
The communication cable must be technically suitable for connecting to the RS485 interface ( > Requirements for the RS485 interface).
The same baud rate (1200 baud, 9600 baud or 19200 baud) must be set in all RS485 devices.
Procedure:
- Disconnect the charging station from voltage sources ( > Disconnecting the product from voltage sources).
- Connect the communication cable to the RS485 interface (see manufacturer's instructions).
- Run the cable to the RS 485-1 slot.
- Dismantle the cable by 80 mm.
- Strip off the conductor insulation by 6 mm.
- Unlock the conductor inserts on the provided 5-pole connector.
- Connect the conductors of the connection cable to the supplied five-pole connector. To do so, plug the conductors into the conductor entries and close the conductor entries. Observe the connector assignment.
- Plug the five-pole connector into the port RS 485-1 on the product. Observe the pin assignment.
- Secure the cable to a strut using a cable tie, and cut off the protruding end of the cable tie with a suitable tool.
- Ensure that the connector is securely in place.
- Ensure that all conductors are correctly connected.
- Ensure that the conductors sit securely in the terminal points.



Also see: