Connect signal source to MFR


Qualified person

Requirements:

Procedure:

  1. Disconnect the charging station from voltage sources Disconnecting the product from voltage sources).
  2. Run the cable to the MFR slot.
  3. Strip 6 mm of the cable insulation at maximum.
  4. 14332778124
  5. Unlock the conductor inserts on the provided 3-pole connector.
  6. 14332776972
  7. Connect the cable to the 3-pole terminal block according to the operating mode. Ensure that the conductors are plugged completely into the terminal points up to their insulation.
  8. 13883077516
  9. Insert the three-pole terminal block with the connected conductors into the MFR slot.
  10. Secure the cable to a strut using a cable tie, and cut off the protruding end of the cable tie with a suitable tool.
  11. Ensure that the terminal block is securely in place.
  12. Ensure that all conductors are correctly connected.
  13. Ensure that the conductors sit securely in the terminal points. Tip: To release the conductors, open the terminal points using a suitable tool.