Multi-EVC operation
Multi-EVC operation allows you to connect up to three SMA EV chargers. In multi-EVC operation mode, all charging stations must be connected to the utility grid on a rolling basis.
The Sunny Home Manager provides the charging stations with information on the number of active charging stations every minute.
In multi-EVC operation mode, if multiple charging stations are charging vehicles and there is a two-phase charging vehicle among the vehicles, this vehicle is limited to single-phase charging for symmetry reasons.
If communication between Sunny Home Manager and the charging stations fails, only single-phase or three-phase charging vehicles can be charged. Two-phase charging vehicles are also limited to single-phase charging in this case. You can set fallback values that take effect in the event of a communication breakdown.
2-phase charging electric vehicle at SMA eCharger
In multi-EVC mode, the maximum charging current is limited to ensure overload protection (maximum charging current/number of active charging stations). If, for example, 3 charging stations are connected to a point of interconnection with a nominal current of 35 A, the charging current is limited as follows:
1 active charging station: 32 A
2 active charging stations: 17.5 A per charging station
3 active charging stations: 11.67 A per charging station
Note that loads with high power consumption can cause the charging stations to disconnect from the utility grid to ensure overload protection.
Charge current limitation