Procedure for commissioning in combination with Sunny Home Manager 2.0
Qualified person
This section describes the procedure of commissioning a charging station that is used in systems with Sunny Home Manager.
It provides an overview of the steps, which must be performed in the prescribed sequence.
Procedure | See | |
---|---|---|
Commission the charging station. | ||
Establish a connection to the user interface of the charging station. There are various connection options to choose from for this:
| ||
If required, change the network configuration on the welcome page. The automatic network configuration recommended by SMA Solar Technology AG via DHCP server is activated by default. Only change the network configurations if the default configuration is not suitable for your network. | Commissioning Assistant | |
Carry out the configuration using the Commissioning Assistant. Select System Manager in the device configuration. | Commissioning Assistant | |
Register the Sunny Home Manager 2.0 and SMA Energy Meter as SMA Speedwire devices. | Commissioning Assistant | |
Add the charging station as a device to a Sunny Portal system with Sunny Home Manager 2.0. | SUNNY PORTAL powered by ennexOS - User Manual |
Also see: