Procedure for commissioning in combination with Sunny Home Manager 2.0


Qualified person

This section describes the procedure of commissioning a charging station that is used in systems with Sunny Home Manager. For commissioning, proceed as described in this section and perform the steps in the given order.

Select no country data set

No country data set may be selected in the commissioning wizard.

  1. Skip this step in the commissioning wizard.

Procedure

See

Commission the charging station.

Commissioning the Product)

Establish a connection to the user interface of the charging station. There are various connection options to choose from for this:

  • Direct connection via Wi-Fi

  • Connection via Wi-Fi in the local network

  • Connection via Ethernet in the local network

Direct connection via Wi-Fi)

Connection in the local network)

If required, change the network configuration on the welcome page. The automatic network configuration recommended by SMA Solar Technology AG via DHCP server is activated by default. Only change the network configurations if the default configuration is not suitable for your network.

Commissioning Assistant

Carry out the configuration using the Commissioning Assistant. Select System Manager in the device configuration.

Commissioning Assistant

Register the Sunny Home Manager 2.0 and SMA Energy Meter as SMA Speedwire devices.
Information: If the SMA eCharger is operated in combination with the Sunny Home Manager 2.0, then only the Sunny Home Manager 2.0 or SMA Energy Meter must be added via the SMA Speedwire device registration in this step. No SMA inverters may be added. SMA inverters are added to the system via the Sunny Home Manager 2.0 and the Sunny Portal.

Commissioning Assistant

Add the charging station as a device to a Sunny Portal system with Sunny Home Manager 2.0.

SUNNY PORTAL powered by ennexOS - User Manual

See also the following video for additional information:

    Also see: