Connecting Signal Source to Digital Input DI 5-6
Qualified person
Additionally required material (not included in the scope of delivery):
1 relay for the grid and PV system protection (break contact)
1 fast-stop switch (break contact)
Requirements:
The signal source must be technically suitable for connection to the digital inputs ( > Technical Data).
Procedure:
- Disconnect the charging station from voltage sources ( > Disconnecting the product from voltage sources).
- Connect the connection cable to the digital signal source (see the manual from manufacturer).
- Run the cable to the DI 5-6 slot.
- Dismantle the cable by 150 mm.
- Strip off the conductor insulation by 6 mm.
- Unlock the conductor entries on the supplied four-pole connector.
- Connect the connection cable to the supplied four-pole connector. To do so, plug the conductors into the conductor entries and close the conductor entries. Observe the connector assignment.
- Plug the 4-pole connector into the port DI 5-6 on the product. Observe the pin assignment.
- Secure the cable to a strut using a cable tie, and cut off the protruding end of the cable tie with a suitable tool.
- Ensure that the connector is securely in place.
- Ensure that all conductors are correctly connected.
- Ensure that the conductors sit securely in the terminal points.



Also see: