Connecting Signal Source to Digital Input DI 5-6


Qualified person

Additionally required material (not included in the scope of delivery):

  • 1 relay for the grid and PV system protection (break contact)

  • 1 fast-stop switch (break contact)

Requirements:

  • The signal source must be technically suitable for connection to the digital inputs Technical Data).

Procedure:

  1. Disconnect the charging station from voltage sources Disconnecting the product from voltage sources).
  2. Connect the connection cable to the digital signal source (see the manual from manufacturer).
  3. Run the cable to the DI 5-6 slot.
  4. Dismantle the cable by 150 mm.
  5. Strip off the conductor insulation by 6 mm.
  6. 11635176716
  7. Unlock the conductor entries on the supplied four-pole connector.
  8. 11635177100
  9. Connect the connection cable to the supplied four-pole connector. To do so, plug the conductors into the conductor entries and close the conductor entries. Observe the connector assignment.
  10. 13883366796
  11. Plug the 4-pole connector into the port DI 5-6 on the product. Observe the pin assignment.
  12. Secure the cable to a strut using a cable tie, and cut off the protruding end of the cable tie with a suitable tool.
  13. Ensure that the connector is securely in place.
  14. Ensure that all conductors are correctly connected.
  15. Ensure that the conductors sit securely in the terminal points.

    Also see: