Connecting the ripple control receiver to DI 1-4
Qualified person
Procedure:
- Connect the connection cable to the ripple control receiver or the remote terminal unit (see the manual from manufacturer).
- Disconnect the charging station from voltage sources ( > Disconnecting the product from voltage sources).
- Strip 6 mm of the cable insulation at maximum.
- Release the conductor entries on the supplied 5-pole plug.
- Connect the conductors of the connection cable to the supplied five-pole connector. To do so, plug the conductors into the conductor entries and close the conductor entries. Observe the connector assignment.
- Plug the five-pole connector into the port DI 1-4 on the product. Observe the pin assignment.
- Ensure that the connector is securely in place.
- Ensure that all conductors are correctly connected.
- Ensure that the conductors sit securely in the terminal points.



Also see: