Resetting the Sunny Home Manager


A Sunny Home Manager must only be reset if it had been installed in another system previously.

Loss of data due to replacement or due to resetting to default settings

If the Sunny Home Manager is reset to the default settings, all data saved in the Sunny Home Manager will be deleted. The data saved in Sunny Portal can be transmitted to the Sunny Home Manager after calling up the PV system again in Sunny Portal. In this case, the PV generation data remains in the Sunny Portal system. Devices that were paired to the Sunny Home Manager via EEBus have to be paired again. The interface for grid management services of the Sunny Home Manager must be deactivated prior to resetting. After resetting the Sunny Home Manager, the interface for grid management services must be activated again. This will assign new, valid Unit IDs to the Modbus devices. Stored Modbus configurations are deleted by resetting the Sunny Home Manager and must be stored again.

Procedure:

  1. Hold down the reset button with a pointed object until the LEDs flash red. This can take up to 6 seconds.
  2. The LEDs flash first green and then red.
  3. When the LEDs start flashing red, release the reset button.
  4. All data stored is deleted and the Sunny Home Manager restarts.
  5. Assign the Sunny Home Manager to the system in Sunny Portal powered by ennexOS again Reassigning the Sunny Home Manager after resetting the system).