Export limitation with Sunny Home Manager 2.0 in accordance with Section 9 of the Renewable Energy Sources Act (EEG)


The system can implement requirements according to the technical requirements of Section 9 of the Renewable Energy Sources Act (EEG). Implementation is carried out using a smart meter gateway SMGW with a connected CLS adapter (FNN control box), which transfers control to the PV system.

You can find compatible devices at: SMA SMART HOME - Compatibility List for the Sunny Home Manager 2.0

Procedure:

  1. Under [Configuration], open [Grid management services] and go to Connecting the FNN control box.
  2. Select [Connecting the FNN control box].
  3. The specifications of the grid operator can be activated under Export limitation in accordance with §9 Renewable Energy Sources Act (EEG).
  4. Click on [Next].
  5. After establishing communication with the Sunny Home Manager 2.0, it is in coupling mode.
  6. Register the Sunny Home Manager SKI in the control box. You have 2 minutes to do this. Provide the Sunny Home Manager SKI to the installer of the metering point operator so that they can register the data in the control box using a special app.
    The SKI is displayed together with the Ship ID as text and QR code during the connection process. The QR code can be downloaded in pdf format.
    You can end the process without having to wait for the final connection.