DC Input
| Maximum PV array power | 165000 Wp STC | 
| Maximum input voltage | 1100 V | 
| MPP voltage range | 200 V to 1000 V | 
| MPP Voltage Range for rated power | 500 V to 800 V | 
| Rated input voltage | 585 V | 
| Minimum input voltage | 200 V | 
| Initial input voltage | 250 V | 
| Maximum usable input current per input with an input voltage < 600 V | 22 A | 
| Maximum usable input current per input with an input voltage > 600 V | 26 A | 
| Maximum short-circuit current per input1) | 40 A | 
| Maximum reverse current into the PV array2) | 0 A | 
| Number of independent MPP inputs | 12 | 
| Strings per MPP input | 2 | 
| Overvoltage category as per IEC 62109-1 | II | 
1) In accordance with IEC 62109-2: ISC PV
2) The topology prevents a reverse current from the inverter in the system