Additionally Required Materials and Equipment
| Material or equipment | Quantity | Explanation | 
|---|---|---|
| Profile rail (length: min. 1100 mm, depth: max. 60 mm, height: 50 mm to 80 mm) | 2 | Required exclusively if the product is intended to be mounted using a profile rail | 
| Threaded ring (M12) | 2 | Only required if the product is to be transported with a lifting gear | 
| Heavy-duty anchor (M10x95) | 4 | Only required if mounted without profile rails: For mounting the device on a wall | 
| Ring terminal lugs (M12) | 4 | To attach to the AC connection cables | 
| Ethanol cleaning agent | 1 | Used to clean terminal lugs | 
| Protective grease | 1 | Only required if cable is made of aluminum: Used to apply to aluminum conductor | 
| Network cable | 1 | To establish communication with the product | 
| Field-assembly RJ45 connector | 2 | Only required if self-assembly network cable is used | 
| Means of transport (e.g., pallet truck) | 1 | Used to transport packed product to installation site | 
| Lifting gear | 1 | Only required if the product is to be transported with a lifting gear | 
| Utility knife | 1 | Used to unpack the product | 
| Flat-blade screwdriver (4 mm) | 1 | For loosening the sealing screw on the attachment bars of the inverter | 
| Phillips screwdriver (PH2) | 1 | For attaching the connecting rod at the bracket parts for the mounting bracket | 
| Tape measure | 1 | For measuring the distances between bore holes for mounting | 
| Marker pen | 1 | For marking the bore holes for mounting | 
| Hammer drill with Ø 12 mm and Ø 14 mm drill bit | 1 | For drilling the bore holes for mounting | 
| Spirit level | 1 | For aligning the mounting bracket | 
| Rubber mallet | 1 | Only required if mounted without profile rails: For securing the expanding screws for mounting | 
| Wrench (AF16) | 1 | Only required if mounted with profile rails: For attaching the mounting bracket | 
| Socket wrench with 16 mm insert | 1 | Only required if mounted with profile rails: For attaching the mounting bracket | 
| Phillips screwdriver (PH3) | 1 | For attaching the product to the mounting bracket | 
| Cable cutter | 1 | For trimming cables | 
| Insulation stripping tool | 1 | For insulating the cable for the AC connection | 
| Press tool | 1 | For attaching the ring terminal lugs to the cables of the AC connection | 
| Hot-air blower | 1 | For attaching the heat-shrink tubings to the AC conductors | 
| Clean cloth | 1 | Used to clean terminal lugs | 
| Brush | 1 | Only required if mounted with profile rails: For cleaning the aluminum conductors | 
| Wrench (AF33) | 1 | For loosening and attaching the swivel nut of the communication connection | 
| Measuring device with a measurement range designed for the maximum AC and DC voltage of the inverter | 1 | For verifying that no voltage is present | 
| Current clamp | 1 | For verifying that no current is present |