Servicing Schedule
Qualified person
Task | Interval |
---|---|
Check the temperature of the inverter and check the inverter for dust contamination. Clean the enclosure if necessary. | Every 6 to 12 months, depending on the environment's dust content |
Check the condition of the air inlet and air outlet and check for dirt and blockages. If necessary, remove dirt and blockages so that the ventilation of the device is ensured again. | Every 6 to 12 months, depending on the environment's dust content |
Check if there is a fan event message or if there are unusual noises when the fan is rotating. Clean or replace the external fans if necessary. | Every 12 months |
Ensure that all cable glands are sufficiently sealed. Seal the cable glands again if necessary. | Every 12 months |
Ensure that all cables are connected correctly and are not damaged. If necessary, correct the connection and replace damaged cables. | Every 6 to 12 months |