Network cable requirements
The cable length and quality affect the quality of the signal. Observe the following cable requirements:
- Cable type: 100BaseTx 
- Cable category: minimum CAT5e 
- Plug type: RJ45 of Cat5, Cat5e or higher 
- Shielding: SF/UTP, S/UTP, SF/FTP or S/FTP 
- Number of insulated conductor pairs and insulated conductor cross-section: at least 2 x 2 x 0.22 mm² 
- Maximum cable length between two nodes when using patch cables: 50 m 
- Maximum cable length between two nodes when using installation cables: 100 m 
- UV-resistant if installed outdoors. 