Connecting the AC Cable of the Outdoor Version of the Battery Cabinet


Qualified person

  1. Ensure that the AC miniature circuit breaker is switched off and that it cannot be reconnected.
  2. 16124466444
  3. Remove the cover of the AC connection area.
  4. Route the AC cable through the cable gland at the bottom into the battery cabinet. To do this, it may be necessary to loosen the cable gland.
  5. Dismantle the AC cables.
  6. 16896061708
  7. Crimp the AC cables using ring terminal lugs Crimping of Ring Terminal Lug).
  8. Remove any cable remnants from the product.
  9. Clean the contact surfaces of all terminal lugs using a clean cloth and ethanol cleaning agent and do not touch the contact surfaces after cleaning.
  10. 16054192652
  11. Attach L and N to the connection rails in accordance with the labeling using M6 hexagon head bolts (tightening torque 5 Nm).
  12. Ensure that all conductors are securely in place.
  13. Reattach the cover of the AC connection area.