Switching on the Sunny Island
Requirements:
- All Sunny Island inverters must be closed ( > Sealing and Closing the Sunny Island).
- The fuse switch-disconnector of the battery fuse must be closed ( > Inserting the Fuse Links in the Fuse Switch-Disconnector).
- The Sunny Island must not have switched itself off ( > Charging the Lead-Acid Battery After Automatic Shutdown (Emergency Charge Mode)).
Procedure:
- For systems with one Sunny Island, press the "On" button on the Sunny Island.
- For systems with up to three Sunny Island inverters, press and hold the "On" button on the master until an acoustic signal sounds.
- For multicluster systems, press and hold the "On" button on each master until an acoustic signal sounds.
- The inverter LED on each Sunny Island inverter is glowing orange and the Sunny Island inverters are in standby mode.