Setting the Solar Charging Mode


You can choose between three different charging modes:

Charging mode

Function

DLM standard

All subordinate charging points (slaves) are charged with the maximum available current.

Surplus PV energy

The vehicle is charged when there is enough excess power to charge with the specified minimum current. Vehicles then charge largely without energy from the grid.

Surplus PV energy + Grid-supplied power

If there is little PV energy available, a fixed amount of electricity is drawn from the grid. The vehicle can then be charged mainly with self-generated energy.

If you use an external meter, you can specify the connection point of the external meter under Load management > DLM External measurement and control > Installation site of the external meter.

Topology

Definition

Utility grid

Meter is installed at the point of interconnection

External load

Meter is installed on an external load

Renewable energy

Meter is installed on a PV system

Requirements:

  • The user interface of the main device (DLM master) must be open and you must be logged in.

Procedure:

  1. In the navigation area, select [Load management].
  2. You can select one of the three charging modes under DLM Solar charging.
    Information: If the Surplus PV energy + grid-supplied power charging mode is selected, the Maximum extra current due to grid supply [A] must be entered to support the PV surplus power. If the two charging points of the charging station are to charge simultaneously at three-phase with 6 A even without surplus PV energy, the value 36 A must be entered.
  3. Under Use solar mode on this charging station, select whether the charging station should work in the selected solar mode.
  4. Click on [Save] to save the changes and [Restart].