Setting the current limit


Requirements:

  • The user interface must be open and you must be logged in.

Procedure:

  1. In the navigation area, select [Installation].
  2. Under [General installation] > Ampacity of the supply line [A] and Installation current limit [A] (Connector 2) set the current limit.
  3. Make sure that the maximum electrical current is not higher than the rated current for the charging point, depending on the AC wiring and the miniature circuit breaker.
  4. Under Number of phases connected to the charging point and Number of phases connected to the charging point (Connector 2) set whether the charging point is connected as a single-phase or three-phase connection. To do so, select [Single-phase system] or [Three-phase system].
  5. Click on [Save] to save the changes and [Restart].