Switching the Inverter On


Requirements:

  • The AC circuit breaker must be correctly rated and mounted.

  • The product must be correctly mounted.

  • All cables for the AC connection, DC connection, and communication must be correctly connected.

  • Unused enclosure openings must be sealed tightly with sealing plugs.

Procedure:

  1. Make sure that the AC cable compartment is closed.
  2. 13877561484
  3. Switch on all 3 DC load-break switches.
  4. Switch the AC voltage supply on.
  5. Green LED is flashing. The inverter is waiting for the input conditions.
  6. Perform the configuration of the inverter Carry out the configuration using the installation assistant).
  7. After approx. 90 seconds, the green LED is permanently on. The inverter is feeding in.
  8. Ensure that the inverter feeds in correctly.

    Also see: