Commissioning the Product


Once you have connected the product to the local network, the user interface login page opens.

5657006348

Login page of the user interface

Requirements:

  • All devices in the local network must be in operation and connected to the product via an Internet router.

  • There must be an active Internet connection.

  • An NTP server must be available in the local network or via the Internet. If there is no NTP server available, the time set in the web browser can be used as system time.

Restart at different system time

An NTP server must be available in the local network or via the Internet. If there is no NTP server available, the time set in the web browser is used as system time. If the difference between the time in the web browser and the system time is more than one minute, the time is synchronized and the product restarted.

Configuring the network settings

  1. To configure the network settings, select Change the network configuration. Observe that the automatic network configuration is set by default via DHCP server and recommended by SMA Solar Technology AG.
    • If the network settings are to be configured manually, select [No].

    • Configure network settings and confirm with [Save].

Starting the installation assistant

  1. Select [Continue] on the login page of the user interface.
  2. Create administrator account and select [Next]. Observe that only one user with administrator authorization can be created on each Data Manager.
  3. The installation assistant will open.
  4. Follow the installation assistant steps listed and make the settings appropriate for your system.
    • Device registration

    • Master or slave configuration

    • Meter configuration

    • Grid management services

  5. A successful commissioning is confirmed by a message.