Generating the I-V Characteristic Curve


Qualified person

Requirements:

  • The user interface must be open and you must be logged in as Installer or Administrator.

Procedure:

  1. Select the product in the focus navigation.
  2. Select the Monitoring menu.
  3. Select the menu item Diagnosis.
  4. Select the I-V characteristic curve.
  5. Select [New measurement].
  6. Use the measurement results to check whether there are any deviations or changes.
  7. If necessary, carry out measures to correct the problems on the PV modules.
  8. Export the results if necessary.

    Also see: