Event 5153 / 99 / 9392


Qualified person

Event number:

Firmware version

Event number

< 3.4.20.R

9392

3.4.20.R

99

Example: 0x0199, 0x0001, 0x0000, 0x0000

Number of the battery module: 01

≥ 3.5.x.R

5153 or 153

Event message:

  • Overcurrent battery charging

LED signal on battery module:

Red LED is flashing quickly.

Corrective measures:

  • Disconnect the system (battery and inverter) from voltage sources.

  • Restart system.

  • If the error persists, contact Service.