LED signals of the battery modules
The LEDs indicate the operating state of the battery modules.
LED signal | Explanation |
---|---|
The green LED is flashing (2 s on and 2 s off) | Waiting for valid operating conditions The conditions for charging and discharge mode are not yet met. As soon as the conditions are met, the battery will start charging and discharging. |
The green LED is glowing | Charge and discharge mode The battery charges or discharges in current-controlled operation. |
The green LED is off | No battery voltage |
The red LED is glowing | Error Operation of the battery has been stopped. In addition, a distinct event message and the corresponding event number will be displayed on the inverter user interface or in the communication product (e.g., SMA Data Manage or Sunny Home Manager). |
Red LED is flashing (0.25 s on, 0.25 s off) | Alarm event regarding temperature or voltage An alarm was triggered during operation. The battery keeps running, but the cause should be checked. |
Red LED is flashing (0.25 s on, 1.25 s off) | Internal battery alarm An alarm was triggered during operation. The battery keeps running, but the cause should be checked. |
The blue LED is flashing slowly (2 seconds on and 2 seconds off) | Communication connection is being established. The battery is establishing a connection with the connected inverter. |
The blue LED is glowing | There is an active connection to the connected inverter. |
Blue LED is off | There is no active connection. |
All 3 LEDs are on | Battery update or booting procedure |