Disconnecting the battery modules from voltage sources
Qualified person
- Disconnect the inverter from voltage sources (see inverter manual).
- Remove the right side cover from each battery module.
- Open the cover of the circuit breaker on each battery module.
- Switch off the circuit breakers one after the other.
- Disconnect all DC connector between the battery modules and to the inverter from each other.
- Check for absence of voltage between the positive and negative terminal of each battery module.
- Close the cover of the circuit breaker on each battery module.
- Attach the side covers.