Possible Connection
The inverter includes the multi-battery function. This enables to charge and discharge several batteries of the same or different type.
Each DC terminal is designed for a maximum charging/discharging current of 10 A. You can choose between the following connection possibilities:
Connection of one, two or three batteries with a charging/discharging current limit of 10 A each.
Connection of two batteries: The first has a charging/discharging current limit of 20 A and the second 10 A.
Connection of one single battery with a charging/discharging current limit of 20 A.
Connection of one single battery with a charging/discharging current limit of 30 A.
In the following sections, you find detailed information as well as a wiring- and connection overview for each connection possibility.