Changing the Display Language
Qualified person
If the language for the country data set is not the language you want to use, you can change the display language as follows:
Overview of rotary switch settings:
A | B | Country data set | Display language | Country |
---|---|---|---|---|
0 | 0 | Default setting | Default setting | Dependent on parameter set |
0 | 1 | Retained | English | Dependent on parameter set |
0 | 2 | Retained | German | Dependent on parameter set |
0 | 3 | Retained | French | Dependent on parameter set |
0 | 4 | Retained | Spanish | Dependent on parameter set |
0 | 5 | Retained | Italian | Dependent on parameter set |
0 | 6 | Retained | Greek | Dependent on parameter set |
0 | 7 | Retained | Czech | Dependent on parameter set |
0 | 8 | Retained | Korean | Dependent on parameter set |
0 | 9 | Retained | Portuguese | Dependent on parameter set |
0 | A | Retained | Dutch | Dependent on parameter set |
0 | B | Retained | Slovenian | Dependent on parameter set |
0 | C | Retained | Bulgarian | Dependent on parameter set |
0 | D | Retained | Polish | Dependent on parameter set |
Procedure:
- Disconnect the inverter from all voltage sources and open the enclosure lid ( > Disconnecting the Inverter from Voltage Sources).
- Determine the rotary switch setting for the desired display language.
- Set the rotary switch A to 0 using a flat-blade screwdriver (blade width: 2.5 mm). This ensures that the selected data country set remains unchanged.
- Set the rotary switch B to the required language using a flat-blade screwdriver (blade width: 2.5 mm).
- Recommission the inverter ( > Commissioning the Inverter).
DANGER
Danger to life due to high voltages
- The inverter adopts the settings after commissioning. This can take up to five minutes.