Sunny Multigate-US
AC Input
Maximum number of connected micro inverters |
12 |
Minimum number of connected micro inverters |
1 |
Maximum input current |
12 A |
AC Output
Rated power at 240 V, 60 Hz |
2,880 W |
Rated grid voltage |
240 V |
Nominal AC voltage* |
2 x 120 V |
AC voltage range |
211 V to 264 V |
Nominal AC current at 240 V |
12 A |
Maximum output current |
12 A |
Total harmonic distortion of the output current with total harmonic distortion of the AC voltage < 2%, and AC power > 50% of the rated power |
≤ 3% |
Rated power frequency |
60 Hz |
AC power frequency |
60 Hz |
Operating range at AC power frequency 60 Hz |
59.3 Hz to 60.5 Hz |
Power factor at rated power |
1 |
Feed-in phases* |
2 |
Connection phases* |
2 |
Overvoltage category |
IV |
* 2 x 120 V split phase
Protective Devices
Overvoltage protection |
Varistors |
Maximum permissible fuse protection |
15 A |
General Data
Width x height x depth, without connection area |
162 mm x 90 mm x 68 mm (6.38 in x 3.54 in x 2.68 in) |
Weight |
0.75 kg (1.65 lbs) |
Operating temperature range |
−40°C to +45°C (−40°F to +113°F) |
Storage temperature |
−40°C to +70°C (−40°F to +158°F) |
Maximum permissible value for relative humidity, non-condensing |
100% |
Maximum operating altitude above mean sea level |
3,000 m (9,840 ft) |
Cooling method |
Convection |
Industrial enclosure for indoor use: degree of protection complying with UL50E |
Type 1 |
Industrial enclosure for outdoor use: degree of protection complying with UL50E |
Type 3 |
Protection class |
I |
Pollution degree |
3 |
Approvals and national standards, as per 09/2013 |
UL1741, IEEE 1547, FCC Part 15 (Class A & B), CAN/CSA C22.2 No. 107.1-1 |
Features
Power-line communication to inverters |
As standard |
Speedwire/Webconnect communication to SMA communication products, RJ45 |
As standard |
Display of the PV system and communication status |
2 LEDs |
Torques
Screw terminals |
0.6 Nm (5.31 in-lb) |
Data Storage Capacity
Energy yield over the day per inverter |
At least 63 days |
Daily yields per inverter |
At least 30 years |
Event messages of the Sunny Multigate for users |
At least 1024 events |
Event messages of the Sunny Multigate for installers |
At least 1024 events |
Event messages per inverter for users |
At least 256 events |
Event messages per inverter for installers |
At least 256 events |