Bring the battery modules to a state of charge of 30%


Information: The 30% refers to the actual target state of charge. The SOC value displayed in Sunny Portal and in the Energy App / 360° App may differ due to the configured charge and discharge stop ranges.

Requirement:

  • You are logged into Sunny Portal powered by ennexOS.

    Procedure:

    1. In the focus navigation, select the inverter to which the battery is connected.
    2. Select the menu Configuration.
    3. Select the menu item Parameters.
    4. Set the value of the parameter Actual target-SOC (Parameter.Bat.TarSoc) to 30%.
    5. Select [Maximum charge/discharge power for charge target] for the parameter Operation Mode Target-SOC (Parameter.Bat.TarSocMod)
    6. Click on [Save].
    7. Once the target SOC has been reached, set the parameter Operation Mode Target-SOC (Parameter.Bat.TarSocMod) to [Off].
    8. Click on [Save].