Sunny Multigate
AC Input
Maximum number of connected micro inverters |
12 |
Minimum number of connected micro inverters |
1 |
Maximum input current |
12 A |
AC Output
Rated power at 230 V, 50 Hz |
2,760 W |
Rated grid voltage |
230 V |
Nominal AC voltage |
220 V / 230 V / 240 V |
AC voltage range |
184 V to 270 V |
Nominal AC current at 220 V |
12 A |
Nominal AC current at 230 V |
12 A |
Nominal AC current at 240 V |
11.5 A |
Maximum output current |
12 A |
Total harmonic distortion of the output current with total harmonic distortion of the AC voltage < 2%, and AC power > 50% of the rated power |
≤ 3% |
Rated power frequency |
50 Hz |
AC power frequency |
50 Hz / 60 Hz |
Operating range at AC power frequency 50 Hz |
45.5 Hz to 63 Hz |
Operating range at AC power frequency 60 Hz |
45.5 Hz to 63 Hz |
Power factor at rated power |
1 |
Feed-in phases |
1 |
Connection phases |
1 |
Overvoltage category as per IEC 60664-1 |
III |
Protective Devices
Overvoltage protection |
Varistors |
Maximum permissible fuse protection |
16 A |
General Data
Width x height x depth, without connection area |
162 mm x 90 mm x 68 mm |
Weight |
0.75 kg |
Climatic category in accordance with IEC 60721-3-4 |
4K1 |
Environmental category |
Not air-conditioned, indoors |
Pollution degree outside the enclosure |
3 |
Pollution degree inside the enclosure |
2 |
Operating temperature range |
−40°C to +45°C |
Maximum permissible value for relative humidity, non-condensing |
100% |
Maximum operating altitude above mean sea level |
3,000 m |
Cooling method |
Convection |
Degree of protection for electronics in accordance with IEC 60529 |
IP20 |
Protection class in accordance with IEC 61140 |
I |
Grid configurations |
TN-C grid configuration, TN-S grid configuration, TN-C-S grid configuration, Delta-IT* |
Approvals and national standards |
VDE0126-1-1, VDE-AR-N-4105, VFR2014, PPC, EN 50438-CZ, NEN-EN 50438, EN 50438, C10/11/2012, AS 4777.3, RD1699, G83/2, CEI0-21, IEC 62109-2** |
* Delta-IT: When using in these networks, the grounding conductor monitoring must be deactivated and an additional grounding connected to the inverter.
** IEC 62109-2: This standard requires that the PV system is connected to Sunny Portal and that the fault alert is activated in Sunny Portal.
Climatic Conditions
As per IEC 60721-3-4, installation type C, class 4K1
Extended temperature range |
−40°C to +45°C |
Extended humidity range |
0% to 100% |
Extended air pressure range |
79.5 kPa to 106 kPa |
As per IEC 60721-3-4, transport type E, class 2K3
Temperature range |
−25°C to +70°C |
Features
Power-line communication to inverters |
As standard |
Speedwire/Webconnect communication to SMA communication products, RJ45 |
As standard |
Display of the PV system and communication status |
2 LEDs |
Torques
Screw terminals |
0.6 Nm |
Data Storage Capacity
Energy yield over the day per inverter |
At least 63 days |
Daily yields per inverter |
At least 30 years |
Event messages of the Sunny Multigate for users |
At least 1,024 events |
Event messages of the Sunny Multigate for installers |
At least 1,024 events |
Event messages per inverter for users |
At least 256 events |
Event messages per inverter for installers |
At least 256 events |