Sunny Boy 240
DC Input
Maximum number of connected PV modules per inverter |
1 |
Maximum input voltage |
45 V |
MPP voltage range at 230 V |
23.0 V to 39.0 V |
Rated input voltage |
29.5 V |
Minimum input voltage |
23.0 V |
Minimum initial input voltage |
23.0 V |
Maximum initial input voltage |
40 V |
Maximum input current |
8.5 A |
Maximum short-circuit current per module* |
12 A |
Overvoltage category as per IEC 60664-1 |
II |
* In accordance with IEC 62109-2: ISC PV
AC Output
Rated power at 230 V, 50 Hz |
230 W |
Maximum apparent AC power |
230 VA |
Rated grid voltage |
230 V |
Nominal AC voltage |
220 V / 230 V / 240 V |
AC voltage range |
184 V to 270 V |
Nominal AC current at 220 V |
1 A |
Nominal AC current at 230 V |
1 A |
Nominal AC current at 240 V |
0.96 A |
Maximum output current |
1 A |
Total harmonic distortion of the output current with total harmonic distortion of the AC voltage < 2%, and AC power > 50% of the rated power |
≤ 3% |
Maximum residual output current |
1 A |
AC inrush current |
123 mA |
Rated power frequency |
50 Hz |
AC power frequency |
50 Hz / 60 Hz |
Operating range at AC power frequency 50 Hz |
45.5 Hz to 63 Hz |
Operating range at AC power frequency 60 Hz |
45.5 Hz to 63 Hz |
Power factor at rated power |
1 |
Feed-in phases |
1 |
Connection phases |
1 |
Overvoltage category with Sunny Multigate as per IEC 60664‑1 |
III |
Protective Devices
DC reverse polarity protection |
Short-circuit diode |
Grid monitoring |
SMA Grid Guard 5 |
AC short-circuit current capability |
Available |
Ground fault monitoring |
Insulation monitoring |
Galvanic isolation |
Available |
General Data
Width x height x depth, without connection area |
188 mm x 199 mm x 43 mm |
Width x height x depth, with connection area |
188 mm x 218 mm x 43 mm |
Weight |
1.3 kg |
Climatic category in accordance with IEC 60721-3-4 |
4K4H |
Environmental category |
outdoors |
Pollution degree outside the enclosure |
3 |
Pollution degree inside the enclosure |
2 |
Operating temperature range |
−40°C to +65°C |
Maximum permissible value for relative humidity, non-condensing |
100% |
Maximum operating altitude above mean sea level |
3,000 m |
Noise emission, typical |
≤ 38 dB(A) |
Power loss in night mode |
< 0.03 W |
Topology |
HF transformer |
Cooling method |
Convection |
Degree of protection for electronics in accordance with IEC 60529 |
IP65 |
Protection class in accordance with IEC 61140 |
I |
Grid configurations |
TN-C grid configuration, TN-S grid configuration, TN-C-S grid configuration, Delta-IT* |
Approvals and national standards |
VDE0126-1-1, VDE-AR-N-4105, VFR2014, PPC, EN 50438-CZ, NEN-EN 50438, EN 50438, C10/11/2012, AS 4777.3, RD1699, G83/2, CEI0-21, IEC 62109-2 |
* Delta-IT: When using in these networks, the grounding conductor monitoring must be deactivated and an additional grounding connected to the inverter.
** IEC 62109-2: This standard requires that the PV system is connected to Sunny Portal and that the fault alert is activated in Sunny Portal.
Climatic Conditions
As per IEC 60721-3-4, installation type C, class 4K4H
Extended temperature range |
−40°C to +65°C |
Extended humidity range |
0% to 100% |
Extended air pressure range |
79.5 kPa to 106 kPa |
As per IEC 60721-3-4, transport type E, class 2K3
Temperature range |
−25°C to +70°C |
Features
DC Connection |
DC plug with DC connector*: DC plug, assembled, MC4 DC plug, assembled, Tyco |
AC connection |
AC cable with two connectors** |
Powerline interface |
As standard |
* The DC connectors supplied are dependent on the order. You can find the SMA order numbers of the DC connectors in this document ( > Spare Parts and Accessories).
** The length of the AC cable depends on the order and is either 1.40 m or 2.0 m.
Efficiency
Maximum efficiency, ηmax |
95.8% |
European efficiency, ηEU |
95.3% |