Connecting the Charging Cable


Qualified person

Requirement:

  • Only use the supplied charging cable or the charging cables approved by SMA as accessories.

  • Do not use adapters or extensions for the charging cable.

NOTICE

Damage to the vehicle due to incorrect connection of the charging cable to the charging station

If the charging cable is not correctly connected to the charging station and the vehicle is charged via it, this may result in damage to the vehicle.

  1. Connect the charging cable and especially the CP cable to the terminal block according to the labeling and the correct line conductor assignment. To do this, proceed as follows.

Procedure:

  1. Disconnect the product from voltage sources Disconnecting the product from voltage sources).
  2. Loosen the bending protection spiral from the cable gland and lead it over the charging cable.
  3. Lead the charging cable through the bending protection spiral and the cable gland into the product
  4. Tighten the bending protection spiral on the cable gland.
  5. 6851540876
  6. Connect the CP cable to the terminal block CP. Open the terminal point with a screwdriver and insert the conductor into the terminal point until it stops.
  7. 6825586316
  8. For EVC22-3AC-10, connect the conductors L1, L2, L3, N and grounding conductor according to the labeling. For EVC7.4-1AC-10, connect the conductors L1, N and grounding conductor according to the labeling. Open the terminal point with a screwdriver and insert each conductor into the respective terminal point until it stops.
  9. Ensure that the terminal points are allocated to the correct conductors.
  10. Tighten the swivel nut on the cable gland hand-tight.