Mounting the Connection Cap


Qualified person

Requirement:

  • Only use the supplied cable glands.

Procedure:

  1. If the AC cable has a diameter of 11 mm to 17 mm, insert the M25 cable gland into the opening of the terminal cover and tighten.
  2. 6842951436
  3. If the AC cable has a diameter of 15 mm to 21 mm, insert the cable gland extension into the opening of the terminal cover and tighten. Then insert the M32 cable gland into the cable gland extension and tighten.
  4. 6842951820
  5. Insert the M25 cable gland with bending protection spiral into the opening of the terminal cover and fasten it from inside with the counter nut.
  6. 7917492492
  7. Put the terminal cover on the enclosure and tighten the 3 screws loosely in the given order, so that the terminal cover still has some play (TX20).