Technical Data


DC Input

STP 24500TL-JP

STP 25000TL-JP

Maximum PV array power

45000 W

45000 W

Maximum input voltage

750 V

1000 V

MPP voltage range at 420 V AC/440 V AC

150 V to 650 V

150 V to 800 V

Rated input voltage

580 V

625 V

Minimum input voltage at 420 V AC/440 V AC

150 V

150 V

Initial input voltage at 420 V AC/440 V AC

188 V

188 V

Maximum input current

2 x 33 A

2 x 33 A

Maximum input current per string

33 A

33 A

Maximum short-circuit current, input A / input  B

43 A / 43 A

43 A / 43 A

Number of independent MPP inputs

2

2

Strings per MPP input

3

3

AC Output

STP 24500TL-JP

STP 25000TL-JP

Rated power at 420 V/440 V, 50 Hz/60 Hz

24500 W

25000 W

Maximum apparent AC power at 420 V/440 V

25000 VA

25000 VA

Nominal AC voltage

3 / PE; 420 V (50 Hz)

3 / PE; 440 V (60 Hz)

3 / PE; 420 V (50 Hz)

3 / PE; 440 V (60 Hz)

AC voltage range

320 V to 480 V

320 V to 480 V

Nominal AC current at 420 V

33.8 A

34.5 A

Nominal AC current at 440 V

32.2 A

32.9 A

Maximum output current

38 A

38 A

Total harmonic distortion

3%

3%

Maximum output current under fault conditions

50 A

50 A

AC power frequency

50 Hz / 60 Hz

50 Hz / 60 Hz

Operating range at AC power frequency 50 Hz

44 Hz to 55 Hz

44 Hz to 55 Hz

Operating range at AC power frequency 60 Hz

54 Hz to 65 Hz

54 Hz to 65 Hz

Power factor at rated power

>0.95

>0.95

Adjustable range of the power factor

-0.8 to 0.8

-0.8 to 0.8

AC connection

3 line conductors, 3 conductors

3 line conductors, 3 conductors

Overvoltage category in accordance with IEC 62109-1

III

III

Protective Devices

DC reverse polarity protection

Short-circuit diode

Protection against module reverse currents

Diode

Input-side disconnection point

DC load-break switch

Utilization category of the input-side disconnection point in accordance with IEC 60947-3

DC-21B

DC overvoltage protection

Surge arrester type II (optional)

AC short-circuit current capability

Current control

Grid monitoring

OV, UV, OF, UF

Ground fault monitoring

Insulation monitoring: Riso > 200 kΩ

All-pole sensitive residual-current monitoring unit

Available

Islanding detection

Active and passive

General Data

Width x height x depth, with DC load-break switch plugged in

661 mm x 682 mm x 264 mm

Weight

61 kg

Length x width x height of the packaging

794 mm x 394 mm x 818 mm

Transport weight

68 kg

Climatic category in accordance with IEC 60721-3-4

4K4H

Operating temperature range

-25°C to +60°C

Maximum permissible value for relative humidity, non-condensing

100%

Maximum operating altitude above mean sea level (MSL)

3000 m

Typical noise emission

51 dB(A)

Power loss in night mode

1 W/90 VA

Topology

Transformerless

Cooling method

SMA OptiCool

Fan connection

Designed for safe disconnection in accordance with DIN EN 62109-1

Degree of protection in accordance with IEC 60529

IP65

Protection class in accordance with IEC 62109-1

I

Climatic Conditions

Installation in accordance with IEC 60721-3-4, Class 4K4H

Extended temperature range

-25 °C to +60 °C

Extended humidity range

0% to 100%

Extended air pressure range

79.5 kPa to 106 kPa

Transport in accordance with IEC 60721-3-2, Class 2K3

Temperature range

-25°C to +70°C

Equipment

DC connection

SUNCLIX DC connector

AC connection

Spring-cage terminal

Display

LC graphic display

SMA Speedwire/Webconnect

As standard

Surge Arrester Type II

Optional

Multifunction relay

Optional

SMA Power Control Module

Optional

Fans

Width x height x depth

60 mm x 60 mm x 25.4 mm

Noise emission, typical

29 dB(A)

Maximum operating altitude

3000 m

Air flow rate

40 m³/h

Torques

Lower enclosure lid screws

2 Nm ± 0.3 Nm

Upper enclosure lid screws

6 Nm ± 0.3 Nm

Screws for DC protective cover

3 Nm ± 0.3 Nm

Screws for DC load-break switch

2 Nm ± 0.2 Nm

Swivel nut of the DC connector

2.0 Nm

Connection multifunction relay / SMA Power Control Module

1.4 Nm

Data Storage Capacity

Energy yields in the course of the day

63 days

Daily yields

30 years

Event messages for users

250 events

Event messages for installers

250 events

Efficiency

STP 24500TL-JP

STP 25000TL-JP

Efficiency in accordance with JIS C 8961

98.0%

98.0%

Maximum efficiency, ηmax

98.7%

98.7%