DC Input


SHP 100-21

SHP 150-21

SHP 172-21

SHP 180-21

Maximum power of PV array

200 kWp

300 kWp

344 kWp

360 kWp

Maximum input voltage

1100 V

1500 V

1500 V

1500 V

MPP voltage range

590 V to 1000 V

880 V to 1450 V

968 V to 1450 V

1012 V to 1450 V

Rated input voltage

590 V

880 V

968 V

1012 V

Minimum input voltage

570 V

855 V

939 V

982 V

Initial input voltage

625 V

940 V

1032 V

1079 V

Maximum input current

180 A

180 A

180 A

180 A

Maximum short-circuit current1)

325 A

325 A

325 A

325 A

Maximum reverse current into the PV modules2)

0 A

0 A

0 A

0 A

Number of independent MPP trackers

1

1

1

1

Number of inputs

1 or 2 (optional) for external PV combiner boxes

1 or 2 (optional) for external PV combiner boxes

1 or 2 (optional) for external PV combiner boxes

1 or 2 (optional) for external PV combiner boxes

Overvoltage category as per IEC 62109-1

II

II

II

II

1) In accordance with IEC 62109-2: ISC PV

2) The topology prevents a reverse current from the inverter in the system