Additionally Required Materials and Equipment
Material or equipment | Quantity | Explanation |
---|---|---|
Profile rail (length: min. 770 mm, depth: 40 mm to 60 mm, height: 50 mm to 83 mm) | 2 | For mounting the product |
Terminal lugs (flange hole: M10) | 2/4 | For connecting the DC cables |
Field-assembly RJ45 connector with metal enclosure | 1-2 | Only required if the network cables are not equipped with RJ45 plugs |
Means of transport (e.g. pallet truck) | 1 | Used to transport packed product to mounting location |
Eye bolt (M10) | 2 | Only required if the product is to be transported with a hoist |
Hoist | 1 | Only required if the product is to be transported with a hoist |
Utility knife | 1 | Used to unpack the product |
Torx screwdriver (TX25) | 1 | Used to attach and remove transport handles |
Torx screwdriver (TX40) | 1 | Used to attach the mounting brackets, to attach the product to the mounting brackets, to attach the connection plate to the product, to connect additional grounding |
Allen key (AF8) | 1 | To attach and remove the enclosure lid and to connect the AC cables |
Allen key (AF16) | 1 | To connect the DC cables |
Measuring device with a measuring range designed for the maximum AC and DC voltage of the product | 1 | For verifying that no voltage is present |
Current clamp | 1 | For verifying that no voltage is present |
Press tool | 1 | Used to attach terminal lugs to DC cables |
Clean cloth | 1 | Used to clean terminal lugs |
Ethanol cleaning agent | 1 | Used to clean terminal lugs |
Brush | 1 | Used to clean aluminum conductor (only necessary if cable is made of aluminum) |
Protective grease | 1 | Used to apply to aluminum conductor (only necessary if cable is made of aluminum) |