Changing the Display Language
Qualified person
If the language for the country data set is not the language you want to use, you can change the display language as follows:
Procedure:
- Disconnect the inverter from all voltage sources and open the enclosure lid ( > Disconnecting the Inverter from Voltage Sources).
- Determine the rotary switch setting for the desired display language. Call up the Technical Information "Overview of the Rotary Switch Settings" at www.SMA-Solar.com.
- Set the rotary switch A to 0 using a flat-blade screwdriver (blade width: 2.5 mm). This ensures that the selected data country set remains unchanged.
- Set the rotary switch B to the required language using a flat-blade screwdriver (blade width: 2.5 mm).
- Recommission the inverter (see service manual at www.SMA-Solar.com).
DANGER
Danger to life due to high voltages

- The inverter adopts the settings after commissioning. This can take up to five minutes.