Decommissioning the Product
Qualified person
Procedure:
- Disconnect the inverter from voltage sources (see inverter manual).
- Switch off the battery (see manual from the battery manufacturer).
- Disconnect the automatic transfer switching device from voltage sources.
- Open the lid of the automatic transfer switching device. To do this, press on the left side of the box.
- Remove the installation cover of the automatic transfer switching device. To do this, loosen the 4 screws (TX20) for fastening the installation cover using a suitable tool.
- Remove the connected cables from the automatic transfer switching device.
- Pull the cable out of the enclosure opening holes.
- Loosen the screw for fastening the automatic transfer switching device on the wall mounting bracket.
- Remove the automatic transfer switching device from the wall mounting bracket.
- Use a suitable screwdriver to loosen the screws securing the wall mounting bracket and remove the washers.
- Remove the wall mounting bracket.