Types of notifications


To be informed of certain events in your system, you can turn on notifications. Notifications inform all system users registered in Sunny Portal, a system group or a system section simultaneously. The language of the sent notifications matches the language assigned to the user account.

E-mails cannot be delivered

If Sunny Portal notifications frequently fail to be delivered, the corresponding e-mail account will be blocked and you will see a message under Configuration > Notifications. The sending of messages is deactivated. Possible causes for this are a full mailbox or technical problems with your provider.

  1. Check your email account. Once the receipt of Sunny Portal notifications is ensured, you can reactivate the sending of notifications.

The following notification types are available:

Notification

Explanation

Alarm AS 5033

For the de jure standard AS 5033, all grounding fault events are sent on occurrence. Sending will be repeated every 24 hours as long as the event is present.

Battery monitoring alarm

This alarm is triggered if at least one of the following criteria is met:

  • The battery has exceeded the upper limit for longer than the specified period of time.

  • The battery has been below the lower limit for longer than the specified period of time.

  • The battery has not sent any new data for longer than the specified period of time.

Alarm IEC 62109-2

For the de jure standard IEC 62109-2/DIN EN 62109-2, all events regarding grounding faults, residual current and the grid disconnecting device are sent on occurrence. Sending will be repeated every 24 hours as long as the event is present.

Alarm communication monitoring

The alarm informs you of communication disturbances of your communication devices

Alarm grid management services

The alarm informs you of events relating to grid management services.

Alarm performance ratio

The alarm informs you when the performance ratio is outside the tolerance.

Alarm inverter comparison

The alarm informs you of the yield warnings of the inverter comparison.

Alarm active power limitation

The alarm informs you of active power limitations in your PV system.

Detailed report

The detailed report informs you of in-depth device data in your system.

Event report

The event report informs you of all events occurring in your PV system.

Infor report

The info report informs you regularly of the yields of your system.

Monitoring of battery capacity

To detect faulty battery modules, the nominal capacity of the battery is monitored. An alarm is triggered if the battery capacity remains below the reference value to be configured for more than one day.

This monitoring is implemented for systems with a commercial battery inverter (STPS60-10, STPS30-20, STPS50-20, SI30-20, SI50-20). Alerts are sent by mail.