Technical Data


DC input

SB1.5-1VL-40

SB2.0-1VL-40

SB2.5-1VL-40

Maximum PV array power

3000 Wp

4000 Wp

5000 Wp

Maximum input voltage

600 V

600 V

600 V

MPP voltage range

160 V to 500 V

210 V to 500 V

260 V to 500 V

Rated input voltage

360 V

360 V

360 V

Minimum input voltage

50 V

50 V

50 V

Initial input voltage

80 V

80 V

80 V

Maximum input current

10 A

10 A

10 A

Maximum short-circuit current*

18 A

18 A

18 A

Maximum reverse current into the PV array

0 A

0 A

0 A

Number of independent MPP inputs

1

1

1

Surge category in accordance with IEC 60664-1

II

II

II

* In accordance with IEC 62109-2: ISC PV

AC Output

SB1.5-1VL-40

SB2.0-1VL-40

SB2.5-1VL-40

Rated power at 230 V, 50 Hz

1500 W

2000 W

2500 W

Maximum apparent power at cos φ = 1

1500 VA

2000 VA

2500 VA

Rated apparent power at cos φ = 1

1500 VA

2000 VA

2500 VA

Rated grid voltage

220 V / 230 V / 240 V

220 V / 230 V / 240 V

220 V / 230 V / 240 V

Rated grid voltage

230 V

230 V

230 V

Voltage range*

180 V to 280 V

180 V to 280 V

180 V to 280 V

Rated current at 220 V

7 A

9 A

11 A

Rated current at 230 V

6.5 A

9 A

11 A

Rated current at 240 V

6.25 A

8.6 A

10.5 A

Maximum output current

7 A

9 A

11 A

Total harmonic distortion of the output current with total harmonic distortion of the AC voltage <2%, and AC power >50% of the rated power

≤3 %

≤3 %

≤3 %

Maximum output current under fault conditions

12 A

16 A

19 A

Inrush current

< 20% of the nominal AC current for a maximum of 10 ms

< 20% of the nominal AC current for a maximum of 10 ms

< 20% of the nominal AC current for a maximum of 10 ms

Rated grid frequency

50 Hz

50 Hz

50 Hz

Grid frequency*

50 Hz / 60 Hz

50 Hz / 60 Hz

50 Hz / 60 Hz

Operating range at grid frequency 50 Hz

45 Hz to 55 Hz

45 Hz to 55 Hz

45 Hz to 55 Hz

Operating range at grid frequency 60 Hz

55 Hz to 65 Hz

55 Hz to 65 Hz

55 Hz to 65 Hz

Power factor at rated power

1

1

1

Displacement power factor cos φ, adjustable

0.8 underexcited to 1 to 0.8 overexcited

0.8 underexcited to 1 to 0.8 overexcited

0.8 underexcited to 1 to 0.8 overexcited

Feed-in phases

1

1

1

Connection phases

1

1

1

Surge category in accordance with IEC 60664-1

III

III

III

* Depending on the configured country data set

Efficiency

SB1.5-1VL-40

SB2.0-1VL-40

SB2.5-1VL-40

Maximum efficiency, ηmax

97.2 %

97.2 %

97.2 %

European weighted efficiency, ηEU

96.1 %

96.4 %

96.7 %

Protective devices

DC reverse polarity protection

Short-circuit diode

Input-side disconnection point

DC load-break switch

AC short-circuit current capability

Current control

Grid monitoring

SMA Grid Guard 10.0

Maximal output overcurrent protection

16 A

Ground fault monitoring

Insulation monitoring: Riso > 1 MΩ

All-pole sensitive residual-current monitoring unit

Available

Active anti-islanding method

Frequency shift

General data

Width x height x depth

460 mm x 357 mm x 122 mm

Weight

9.2 kg

Length x width x height of the packaging

597 mm x 399 mm x 238 mm

Weight including packaging

11.5 kg

Climatic category in accordance with IEC 60721-3-4

4K4H

Environmental category

Outdoors

Pollution degree outside the inverter

3

Pollution degree inside the inverter

2

Operating temperature range

-40°C to +60°C

Max. permissible value for relative humidity (condensing)

100 %

Maximum operating altitude above mean sea level (MSL)

3000 m

Noise emission, typical

< 25 dB

Power loss in night mode

5 W

Maximum data volume per inverter with Speedwire/Webconnect

550 MB/month

Additional data volume when using the Sunny Portal live interface

600 kB/hour

Power control / Demand response (DRED)

Communication via Modbus interface

Export limiting according to AS/NZS 4777.2

EMETER-20, HM-20

Demand response mode in accordance with AS/NZS 4777.2

DRM0

Topology

Transformerless (Non-isolated)

Cooling method

Convection

Degree of protection in accordance with IEC 60529

IP65

Protection class in accordance with IEC 62477

I

Radio technology

WLAN 802.11 b/g/n

Radio spectrum

2.4 GHz

Maximum transmission power

100 mW

Quantity maximum detectable Wi-Fi networks

32

Grid configurations

TN-C, TN-S, TN-CS, TT (if VN_PE < 30 V), IT, Delta IT, split phase

Climatic conditions

Installation in accordance with IEC 60721-3-4, Class 4K4H

Extended temperature range

-40°C to +60°C

Extended humidity range

0 % to 100 %

Extended air pressure range

79.5 kPa to 106 kPa

Transport in accordance with IEC 60721-3-4, Class 2K3

Extended temperature range

-25°C to +70°C

Equipment

DC terminal

SUNCLIX DC connector

AC connection

Spring-cage terminal

Speedwire interface

As standard

Webconnect interface

As standard

Wi-Fi

As standard

DC Load-Break Switch

Electrical endurance in the event of short circuit, at nominal current of 10 A

At least 50 switching operations

Maximum switching current

35 A

Maximum switching voltage

800 V

Maximum PV power

11 kW

Torques

Screws wall mounting

Hand-tight

Screws of terminal cover

3.5 Nm

SUNCLIX swivel nut

2.0 Nm

AC swivel nut

Hand-tight

Network swivel nut

Hand-tight

Additional grounding terminal

6.0 Nm

Data Storage Capacity

Energy yields in the course of the day

63 days

Daily yields

30 years

Event messages for users

1024 events

Event messages for installers

1024 events