Usable power when using the STP10.0-3SE-40 together with Varta.wall
Varta.wall 10 | Varta.wall 15 | Varta.wall 20 | |
|---|---|---|---|
10.0 kWh | 15.0 kWh | 20 kWh | |
Voltage range of battery | 168 V to 226 V | 252 V to 340 V | 336 V to 453.6 V |
Maximum current | 22 A | ||
Maximum current | 26 A | ||
Maximum charging power | 3.7 kW to 5.0 kW | 5.5 kW to 7.5 kW | 7.4 kW to 10 kW |
Maximum discharge power | 4.4 kW to 5.9 kW | 6.6 kW to 8.8 kW | 8.7 kW to 10.6 kW |