Technical Data
DC Input
STP 15000TL-10 |
STP 17000TL-10 | |
---|---|---|
Maximum DC power at cos φ = 1 |
15,340 W |
17,410 W |
Maximum input voltage |
1,000 V |
1,000 V |
MPP voltage range |
360 V to 800 V |
400 V to 800 V |
Rated input voltage |
600 V |
600 V |
Minimum input voltage |
150 V |
150 V |
Initial input voltage |
188 V |
188 V |
Maximum input current, input A |
33 A |
33 A |
Maximum input current, input B |
11 A |
11 A |
Maximum input current per string, input A* |
40 A |
40 A |
Maximum input current per string, input B* |
12.5 A |
12.5 A |
Maximum short-circuit current, input A** |
50 A |
50 A |
Maximum short-circuit current, input B** |
17 A |
17 A |
Maximum reverse current from the inverter in the system for max. 1 ms |
0 A |
0 A |
Number of independent MPP inputs |
2 |
2 |
Strings per MPP input, input A |
5 |
5 |
Strings per MPP input, input B |
1 |
1 |
Overvoltage category in accordance with IEC 60664-1 |
II |
II |
* To be observed in the event of a short circuit of the electronic string fuse.
** In accordance with IEC 62109-2: ISC PV
AC Output
STP 15000TL-10 |
STP 17000TL-10 | |
---|---|---|
Rated power at 230 V, 50 Hz |
15,000 W |
17,000 W |
Maximum apparent AC power |
15,000 VA |
17,000 VA |
Rated grid voltage |
∼3/N/PE, 230 V / 400 V |
∼3/N/PE, 230 V / 400 V |
Nominal AC voltage |
220 V, 230 V, 240 V |
220 V, 230 V, 240 V |
AC voltage range* |
160 V to 280 V |
160 V to 280 V |
Nominal AC current at 230 V |
21.7 A |
24.6 A |
Maximum output current |
24 A |
24.6 A |
Total harmonic distortion of the output current with total harmonic distortion of the AC voltage < 2%, and AC power > 50% of the rated power |
≤3% |
≤2.6% |
Inrush current |
< 20% of the nominal AC current for a maximum of 10 ms |
< 20% of the nominal AC current for a maximum of 10 ms |
Maximum output current under fault conditions |
0.05 kA |
0.05 kA |
Rated power frequency |
50 Hz |
50 Hz |
AC power frequency* |
50 Hz / 60 Hz |
50 Hz / 60 Hz |
Operating range at AC power frequency 50 Hz |
44 Hz to 55 Hz |
44 Hz to 55 Hz |
Operating range at AC power frequency 60 Hz |
54 Hz to 65 Hz |
54 Hz to 65 Hz |
Power factor at rated power |
1 |
1 |
Displacement power factor cos φ, adjustable |
0 leading to 0 lagging |
0 leading to 0 lagging |
Feed-in phases |
3 |
3 |
Connection phases |
3 |
3 |
Overvoltage category in accordance with IEC 60664-1 |
III |
III |
* depending on the configured country data set
Protective Devices
DC reverse polarity protection |
Short-circuit diode, electronic string fuse |
Protection against reverse currents |
Electronic string fuse |
Input-side disconnection point |
Electronic Solar Switch, SUNCLIX DC connector |
DC overvoltage protection |
Thermally monitored varistors or surge arresters type II (optional) |
AC short-circuit current capability |
Current control |
Grid monitoring |
SMA Grid Guard 4 |
Maximum permissible fuse protection |
50 A |
Ground-fault monitoring for STP 15000TL-10 |
Insulation monitoring: Riso > 366.3 kΩ |
Ground-fault monitoring for STP 17000TL-10 |
Insulation monitoring: Riso > 323.4 kΩ |
All-pole sensitive residual-current monitoring unit |
Available |
Electronic string-current monitoring |
Available |
String-failure detection |
Available |
General Data
Width x height x depth, with Electronic Solar Switch |
665 mm x 690 mm x 265 mm |
Weight |
59 kg |
Length x width x height of the packaging |
780 mm x 380 mm x 790 mm |
Transport weight |
65 kg |
Climatic category in accordance with IEC 60721-3-3 |
4K4H |
Environmental category |
Outdoors |
Pollution degree outside the inverter |
3 |
Pollution degree inside the inverter |
2 |
Operating temperature range |
-25°C to +60°C |
Maximum permissible value for relative humidity, non-condensing |
100% |
Maximum operating altitude above mean sea level (MSL) |
3,000 m |
Typical noise emission |
51 dB(A) |
Power loss in night mode |
<1 W |
Maximum data volume per inverter with Speedwire/Webconnect |
550 MB/month |
Additional data volume when using the Sunny Portal live interface |
600 kB/hour |
Topology |
transformerless |
Cooling method |
SMA OptiCool |
Degree of protection in accordance with IEC 60529 |
IP65 |
Protection class in accordance with IEC 61140 |
I |
Grid configurations |
TN-C, TN-S, TN-C-S, TT (when VN_PE < 30 V) |
Approvals and national standards, as per 10/2014* |
AS 4777, BDEW 2008, C10/11:2012, CE, CEI 0-16, CEI 0-21, EN 50438, G59/3, IEC 60068-2, IEC 61727, MEA/PEA, IEC 62109-2, NEN 50438, PPC, PPDS, RD 1699, RD 661/2007, SI4777, UTE C15-712-1, VDE 0126-1-1, VDE AR-N 4105, VFR 2013, VFR 2014 |
* C10/11:2012: only possible if the three-phase line-to-line voltage is 400 V.
EN 50438: does not apply to all national appendices of EN 50438.
IEC 62109-2: This standard requires that either the multifunction relay in the inverter is used as fault indicator or that the inverter is connected to Sunny Portal and that the fault alert is activated in Sunny Portal.
NRS 97-2-1: This standard requires a separate label be attached to the AC distribution board to indicate the AC-side disconnection of the inverter in case of a grid failure (for further details, see NRS 97-2-1, Sect. 4.2.7.1 and 4.2.7.2).
MEA/PEA: only applicable to STP 17000TL-10
Climatic Conditions
Installation in accordance with IEC 60721-3-3, Class 4K4H
Extended temperature range |
-25°C to +60°C |
Extended humidity range |
0% to 100% |
Extended air pressure range |
79.5 kPa to 106 kPa |
Transport in accordance with IEC 60721-3-2, Class 2K3
Temperature range |
-25°C to +70°C |
Electronic Solar Switch
Electrical endurance in the event of short circuit, at nominal current of 33 A |
At least 50 switching operations |
Maximum switching current |
33 A |
Maximum switching voltage |
1,000 V |
Maximum power |
20 kW |
Degree of protection when plugged in |
IP65 |
Degree of protection when unplugged |
IP21 |
Features
DC Connection |
SUNCLIX DC connector |
AC connection |
Spring-cage terminal |
Display |
LC graphic display |
BLUETOOTH |
As standard |
RS485, galvanically isolated |
Optional |
Speedwire/Webconnect |
Optional |
Multifunction Relay |
Optional |
SMA Power Control Module |
Optional |
Torques
Upper enclosure lid screws |
6 Nm ± 0.3 Nm |
Lower enclosure lid screws |
2 Nm ± 0.3 Nm |
Screws for DC protective cover |
3.5 Nm |
Cylindrical screws M5x10 for securing the enclosure to the rear panel |
3.5 Nm |
Additional grounding |
6.0 Nm |
SUNCLIX swivel nut |
2.0 Nm |
RS485 communication or Speedwire/Webconnect connection |
1.5 Nm |
Multi-function relay connection |
1.5 Nm |
Data Storage Capacity
Energy yields in the course of the day |
63 days |
Daily yields |
30 years |
Event messages for users |
250 events |
Event messages for installers |
250 events |
Efficiency
Maximum efficiency, ηmax |
98.2% |
European efficiency, ηEU |
97.8% |