IMPORTANT SAFETY INFORMATION


Keep the manual for future reference.

This section contains safety information that must be observed at all times when working.

DANGER

Danger to life due to electric shock when touching live system components in case of a ground fault

If a ground fault occurs, parts of the system may still be live. Touching live parts and cables results in death or lethal injuries due to electric shock.

  1. Disconnect the system from voltage sources and make sure it cannot be reconnected before working on the device.
  2. Only touch the cables of the PV modules on their insulation.
  3. Do not touch any parts of the substructure or frame of the PV array.
  4. Do not connect PV strings with ground faults to the inverter.
  5. Once disconnected from voltage sources, wait five minutes before touching any parts of the PV system or the system.

WARNING

Danger to life due to fire and deflagration

In rare cases, an explosive gas mixture can be generated inside the inverter under fault conditions. In this state, switching operations can cause a fire and, in very rare cases, a deflagration inside the inverter. Death or lethal injuries due to the spread of a fire can result.

  1. In case of failure, do not perform any direct actions on the inverter.
  2. In case of failure, ensure that unauthorized persons have no access to the product.
  3. In case of failure, disconnect the PV module from the inverter via an external disconnection device. If there is no disconnecting device present, wait until no more DC power is applied to the inverter.
  4. In case of failure, disconnect the battery from the inverter via an external disconnection device. Do not operate the DC load-break switch on the inverter.
  5. In the event of a fault, disconnect the AC circuit breaker, or keep it disconnected in case it has already tripped, and secure it against reconnection.

WARNING

Danger to life due to fire or explosion when batteries are fully discharged

A fire may occur due to incorrect charging of fully discharged batteries. This can result in death or serious injury.

  1. Before commissioning the system, verify that the battery is not fully discharged.
  2. Do not commission the system if the battery is fully discharged.
  3. If the battery is fully discharged, contact the battery manufacturer for further proceedings.
  4. Only charge fully discharged batteries as instructed by the battery manufacturer.

Requirements in the documents enclosed with each product must be observed.

This document supplements the documents that are enclosed with each product and does not replace any locally applicable codes or standards.

  1. Read and observe the requirements in the documents enclosed with the products in addition to the requirements stated below.