System requirements for the Energy Management powered by ennexOS
- No Sunny Home Manager 2.0 can be configured as a main device in the system.
- A product powered by ennexOS ( > Validity) must be registered and configured as the System Manager (see the user manual "Operation of the User Interface of Products powered by ennexOS").
- Energy management must be enabled on the user interface of the System Manager.
- The system must be captured in Sunny Portal powered by ennexOS.
- Battery control via a third-party energy management system (e.g., Modbus RTU) must not be enabled.
- An energy meter must be installed at the point of interconnection.
- Depending on normative requirements, the limitation at the point of interconnection must be correctly set.
- The system must be configured with self-consumption.
- In systems with more than 5 inverters, an SMA Data Manager M must be configured as the System Manager in certain cases (see technical information "Compatibility of SMA Devices").
- PV modules must be available and connected in the system.
- The system settings for tariffs, system location, system power and PV module alignment must be correct.