Commissioning Procedure
Qualified person

Commissioning an inverter that is captured in a communication device
When the inverter is captured in a communication device, the communication device (e.g. SMA Data Manager) is the unit for configuring the total system. The configuration is transferred to all inverters in the system. The system password assigned via the communication device is also the password for the user interface of the inverter.
- Commission the inverter ( > Commissioning the Inverter).
- The initial configuration of the inverter is made via the communication device. Use the configuration file for this. The configuration is transferred to the inverter and the settings of the inverter are overwritten.
- Deactivate the Webconnect function of the inverter via the Sunny Portal. This prevents unnecessary connection attempts of the inverter with Sunny Portal.
This section describes the commissioning procedure and gives an overview of the steps you must perform in the prescribed order.
|
Procedure |
See | |
|---|---|---|
|
|
Commission the inverter. | |
|
|
Establish a connection to the user interface of the inverter. There are various connection options to choose from for this:
| |
|
|
Log into the user interface. | |
|
|
Start the installation assistant and follow the installation assistant steps. For this, skip the step Country data set with Save and next. | |
|
|
Make further inverter settings as needed. | |