Additionally Required Materials and Equipment
Material or equipment | Quantity | Explanation |
---|---|---|
Profile rail (length: min. 770 mm (30.3 in), depth: max. 60 mm (2.4), height: 50 mm to 80 mm (2 in to 3 in) | 2 | For mounting the product |
Conduit (trade size: 76.2 mm (3 in) or smaller with suitable reducer bush) for the DC connection | 1 | Only necessary if DC cables must be laid in one conduit |
Raintight or liquidtight conduit fitting (trade size: 76.2 mm (3 in) or smaller with suitable reducer bush) for DC connection | 1 | Only necessary if DC cables must be laid in one conduit |
Conduit (trade size: 63.5 mm (2.5 in) or smaller with suitable reducer bush) for DC connection | 1 | Only necessary if AC cables must be laid in one conduit |
Raintight or liquidtight conduit fitting (trade size: 63.5 mm (2.5 in) or smaller with suitable reducer bush) for AC connection | 1 | Only necessary if AC cables must be laid in one conduit |
Conduit (trade size: 19.05 mm (0.75 in) or smaller with suitable reducer bush) for network connection | 1 | Only necessary if network cables must be laid in one conduit |
Raintight or liquidtight conduit fitting (trade size: 19.05 mm (0.75 in) or smaller with suitable reducer bush) for network connection | 1 | Only necessary if network cables must be laid in one conduit |
Terminal lugs (flange hole: M10) | 2 | Used for positive and negative DC cable |
Terminal lugs (flange hole: M6) | 1 | Used for equipment grounding conductor |
RJ45 plugs, field assembly | 1-2 | Only required if the network cables are not equipped with RJ45 plugs |
Means of transport (e.g. pallet truck) | 1 | Used to transport packed product to mounting location |
Eye bolt (M10) | 2 | Only required if the product is to be transported with a hoist |
Hoist | 1 | Only required if the product is to be transported with a hoist |
Utility knife | 1 | Used to unpack the product |
Torx screwdriver (TX25) | 1 | Used to attach and remove transport handles and enclosure lid |
Torx screwdriver (TX40) | 1 | Used to attach mounting brackets, inverters to mounting brackets, connecting plate to inverter; used to connect equipment grounding conductor of PV array |
Allen key (AF5) | 1 | Used for connecting grounding conductor |
Allen key (AF8) | 1 | Used for connecting L1, L2 an L3 |
Measuring device with a measurement range designed for the maximum AC and DC voltage of the inverter | 1 | For verifying that no voltage is present |
Current clamp | 1 | For verifying that no voltage is present |
Press tool | 1 | Used to attach terminal lugs to DC cables |
Clean cloth | 1 | Used to clean terminal lugs |
Ethanol cleaning agent | 1 | Used to clean terminal lugs |
Brush | 1 | Used to clean aluminum conductor (only necessary if cable is made of aluminum) |
Protective grease | 1 | Used to apply to aluminum conductor (only necessary if cable is made of aluminum) |