Additionally Required Materials and Equipment


Material or equipment

Quantity

Explanation

Profile rail (length: min. 770 mm (30.3 in), depth: max. 60 mm (2.4), height: 50 mm to 80 mm (2 in to 3 in)

2

For mounting the product

Conduit (trade size: 76.2 mm (3 in) or smaller with suitable reducer bush) for the DC connection

1

Only necessary if DC cables must be laid in one conduit

Raintight or liquidtight conduit fitting (trade size: 76.2 mm (3 in) or smaller with suitable reducer bush) for DC connection

1

Only necessary if DC cables must be laid in one conduit

Conduit (trade size: 63.5 mm (2.5 in) or smaller with suitable reducer bush) for DC connection

1

Only necessary if AC cables must be laid in one conduit

Raintight or liquidtight conduit fitting (trade size: 63.5 mm (2.5 in) or smaller with suitable reducer bush) for AC connection

1

Only necessary if AC cables must be laid in one conduit

Conduit (trade size: 19.05 mm (0.75 in) or smaller with suitable reducer bush) for network connection

1

Only necessary if network cables must be laid in one conduit

Raintight or liquidtight conduit fitting (trade size: 19.05 mm (0.75 in) or smaller with suitable reducer bush) for network connection

1

Only necessary if network cables must be laid in one conduit

Terminal lugs (flange hole: M10)

2

Used for positive and negative DC cable

Terminal lugs (flange hole: M6)

1

Used for equipment grounding conductor

RJ45 plugs, field assembly

1-2

Only required if the network cables are not equipped with RJ45 plugs

Means of transport (e.g. pallet truck)

1

Used to transport packed product to mounting location

Eye bolt (M10)

2

Only required if the product is to be transported with a hoist

Hoist

1

Only required if the product is to be transported with a hoist

Utility knife

1

Used to unpack the product

Torx screwdriver (TX25)

1

Used to attach and remove transport handles and enclosure lid

Torx screwdriver (TX40)

1

Used to attach mounting brackets, inverters to mounting brackets, connecting plate to inverter; used to connect equipment grounding conductor of PV array

Allen key (AF5)

1

Used for connecting grounding conductor

Allen key (AF8)

1

Used for connecting L1, L2 an L3

Measuring device with a measurement range designed for the maximum AC and DC voltage of the inverter

1

For verifying that no voltage is present

Current clamp

1

For verifying that no voltage is present

Press tool

1

Used to attach terminal lugs to DC cables

Clean cloth

1

Used to clean terminal lugs

Ethanol cleaning agent

1

Used to clean terminal lugs

Brush

1

Used to clean aluminum conductor (only necessary if cable is made of aluminum)

Protective grease

1

Used to apply to aluminum conductor (only necessary if cable is made of aluminum)